Lapse Rates: ELR, DALR and SALR
A lapse rate is the rate at which air temperature falls with height. Meteorology uses three: the environmental lapse rate of the air at rest, measured by soundings, and the dry and saturated adiabatic lapse rates at which rising air cools. Comparing them decides whether the air is stable or unstable.
A lapse rate is the rate at which air temperature falls with increasing height. Three lapse rates run through aviation meteorology, and most errors in the subject come from using the wrong one. The environmental lapse rate (ELR) describes the air as it is, measured by a sounding. The dry adiabatic lapse rate (DALR) and the saturated adiabatic lapse rate (SALR) describe what happens to a parcel of air when it is made to rise or sink. Set side by side, they decide whether the air is stable or unstable, where cloud forms, and what kind of cloud it is.
This article covers the rates themselves, the rules of thumb built on them and the calculations that EASA and FAA examinations ask for. The weather that each kind of stability brings is described in atmospheric stability.
What a lapse rate is
A lapse rate is positive when temperature falls with height, which is the normal state of the troposphere. Zero lapse rate is an isothermal layer; a negative lapse rate, temperature rising with height, is an inversion (see temperature inversions). The tropopause is defined by the lapse rate too: it is taken as the lowest level at which the lapse rate falls to 2 °C per km (0.2 °C per 100 m) or less. In the ISA it lies at 11 km (36,090 ft), where the temperature stops falling at −56.5 °C; a climbing crew finds the real one where the outside air temperature stops falling.
Rates are quoted per 100 m in EASA material and per 1,000 ft in the cockpit and in FAA material. Since 1,000 ft is about 305 m, 1 °C per 100 m is about 3 °C per 1,000 ft, and 0.65 °C per 100 m is 1.98 °C per 1,000 ft.
Environmental lapse rate
The environmental lapse rate is the actual change of temperature with height at a given place and time, as measured by radiosonde ascents and plotted on a tephigram or skew-T diagram. It is a snapshot of air at rest, not a rate at which any air cools, and it changes from day to day and through the day. The ICAO Standard Atmosphere uses a fixed average of 0.65 °C per 100 m, 1.98 °C per 1,000 ft, rounded to 2 °C (3.5 °F) per 1,000 ft, up to 11 km (see international standard atmosphere).
The real profile departs from that average in predictable ways:
- Heating from below steepens the ELR. Sunshine on dry ground, or cold air moving over a warmer surface, destabilizes the lowest layer; over strongly heated ground on a hot afternoon the ELR can exceed the DALR.
- Cooling from below, by radiation on a clear night or warm air moving over a colder surface, makes it shallower or inverts it.
- Cooling aloft steepens it; warming aloft, as in subsiding air under an anticyclone, flattens it and can form a subsidence inversion.
- Mechanical mixing in the friction layer drives the lapse rate within the mixed layer toward the DALR and leaves a turbulence inversion at its top, under which stratus or stratocumulus spreads with a flat top.

Dry adiabatic lapse rate
An adiabatic change of temperature is caused by compression or expansion alone, with no heat exchanged with the surroundings. Rising air meets lower pressure, expands and cools; sinking air is compressed and warms. As long as no water condenses or evaporates, the rate is fixed: the dry adiabatic lapse rate is 1 °C per 100 m, about 3 °C (5.4 °F) per 1,000 ft. It applies to any unsaturated parcel, whether its relative humidity is 10% or 99%, and to sinking air as much as to rising air.
While the parcel's temperature falls at the DALR, its dew point also falls, but much more slowly: about 0.5 °C per 1,000 ft in EASA texts, about 1 °F per 1,000 ft in FAA material. The two converge, and where they meet the parcel is saturated. That height is the condensation level, the base of the cloud.
Exam tip: unsaturated air forced up a hillside from +20 °C to 3,000 ft cools at 3 °C per 1,000 ft and arrives at +11 °C. The ISA's 2 °C per 1,000 ft would give +14 °C, the classic wrong answer: the ISA rate and the ELR describe air at rest, the DALR the moving parcel.
Saturated adiabatic lapse rate
Once the parcel is saturated, further ascent condenses water vapor into cloud, and condensation releases latent heat into the parcel. That heat offsets part of the cooling by expansion, so saturated air cools more slowly: the saturated adiabatic lapse rate is always less than the DALR.
Unlike the DALR it is not constant, because it depends on how much vapor condenses. Warm air holds more water vapor, so the SALR is lowest in warm, moist air near the surface and in the tropics. In cold air little vapor is left to condense, so the SALR increases with altitude and latitude and approaches the DALR. Different texts therefore quote different figures:
| Source | SALR figure |
|---|---|
| EASA ATPL texts | About 0.6 °C per 100 m (1.8 °C per 1,000 ft), near the surface in temperate latitudes |
| PPL, CPL and IR questions | Often rounded to 1.5 °C per 1,000 ft |
| FAA Pilot's Handbook of Aeronautical Knowledge | 1.1 to 2.8 °C (2 to 5 °F) per 1,000 ft |
These are approximations of one variable rate, not rival values. In a calculation, use the figure the question gives.
Sinking air in which there is no cloud to evaporate warms at the DALR. This asymmetry, a slow saturated rate going up and the full dry rate coming down once the water has fallen out as rain, is what makes the föhn effect.
Stability from comparing lapse rates
A parcel lifted a little way is compared with the air around it at its new level. If it is colder, it is denser and sinks back: the air is stable. If it is warmer, it keeps rising: the air is unstable. Since the parcel cools at the DALR or the SALR while the environment follows the ELR, the test reduces to where the ELR lies:
| ELR compared with the adiabatic rates | State | EASA examples (per 100 m) | Examples per 1,000 ft |
|---|---|---|---|
| Less than the SALR | Absolutely stable | 0.4 °C | Any inversion or isothermal layer |
| Between the SALR and the DALR | Conditionally unstable | 0.8 °C | 2 °C or 2.5 °C |
| Greater than the DALR | Absolutely unstable | 1.2 °C | 3.5 °C |
| Equal to the DALR (dry) or the SALR (saturated) | Neutral | 1.0 °C for dry air | 3 °C for dry air |
Conditional instability, the middle row, is the common case; measured against the textbook rates, even the ISA profile lies in it. The condition is saturation: an unsaturated parcel is stable, a saturated one is not. What turns such a sounding into showers or thunderstorms is a trigger, such as surface heating, high ground or a front, that lifts the air far enough. Stability also changes as the profile changes: a morning ELR of 2 °C per 1,000 ft can become absolutely unstable near the ground by mid-afternoon over heated land.

Cloud base estimation
Convective cloud base estimation uses the convergence of temperature and dew point in rising air. The temperature falls about 3 °C per 1,000 ft and the dew point about 0.5 °C, so the spread closes at about 2.5 °C per 1,000 ft:
Cumulus base (ft above the surface) ≈ 400 × (temperature − dew point) in °C
In metric terms this is about 120 m per degree of spread. With Fahrenheit readings the FAA uses a convergence of 4.4 °F per 1,000 ft (5.4 °F for the temperature, 1 °F for the dew point): divide the spread by 4.4 and multiply by 1,000 ft. The FAA's own example, 85 °F and a dew point of 71 °F, gives 14 ÷ 4.4 × 1,000, a base of about 3,180 ft AGL.

Three cautions apply. The answer is a height above the station; add the aerodrome elevation for an altitude. The rule fits cumulus formed by convection in a well-mixed layer, not stratus, fog or frontal cloud. And distractors in exam questions come from mixing the scales: a 10 °C spread divided by the Fahrenheit factor 4.4 gives a wrong 2,300 ft, divided by 2 a wrong 5,000 ft.
Worked examples
1. Cloud base and altitude. An aerodrome at 1,500 ft AMSL reports 21 °C and a dew point of 11 °C. The spread is 10 °C, so the cumulus base is about 4,000 ft above the aerodrome, or 5,500 ft AMSL.
2. Conditional instability and the trigger. A sea-level station reports 20 °C, dew point 12 °C, and the morning sounding gives an ELR of 2 °C per 1,000 ft. Take the DALR as 3 °C, the dew point lapse as 0.5 °C and the SALR as 1.5 °C per 1,000 ft.
- The spread of 8 °C puts the condensation level at about 3,200 ft. A parcel lifted there has cooled to 20 − 3 × 3.2 = 10.4 °C, and its dew point has fallen to 12 − 0.5 × 3.2 = 10.4 °C, so it is just saturated.
- The environment at 3,200 ft is 20 − 2 × 3.2 = 13.6 °C. The parcel is 3.2 °C colder and, left alone, would sink back: the air is stable for unsaturated parcels.
- Above the base the parcel cools at 1.5 °C per 1,000 ft against the environment's 2 °C, so the gap closes by 0.5 °C per 1,000 ft. It closes after 6,400 ft, at about 9,600 ft. Lifted beyond that level, by a front or a range of hills, the parcel is warmer than its surroundings and rises on its own. The same sounding gives a quiet day without a trigger and towering cloud with one.
3. Föhn. Air at sea level at 16 °C with a dew point of 12 °C is forced over a ridge 8,000 ft high, raining out on the windward side. With the EASA SALR of 1.8 °C per 1,000 ft:
| Stage | Height | Rate | Temperature |
|---|---|---|---|
| Windward, at sea level | 0 ft | 16 °C | |
| Cloud base (spread 4 °C × 400 ft) | 1,600 ft | DALR, 3 °C per 1,000 ft | 11.2 °C |
| Crest | 8,000 ft | SALR, 1.8 °C per 1,000 ft over 6,400 ft | about −0.3 °C |
| Lee side, at sea level | 0 ft | DALR, 3 °C per 1,000 ft over 8,000 ft | about +24 °C |
The lee side is about 8 °C warmer than the windward side at the same level, and much drier. With the PPL figure of 1.5 °C for the SALR the answer is about +26 °C, which is why the question's figure must be used.

4. Temperature at a level and the freezing level. For air at rest, use the ELR, and failing a sounding the 2 °C per 1,000 ft of the ISA. An aerodrome at 1,000 ft AMSL reporting +6 °C suggests a freezing level near 4,000 ft AMSL: 6 °C of cooling takes about 3,000 ft. If −12 °C is measured at FL110, the temperature expected at FL140 is about −18 °C.
Lapse rates in flight planning
The same numbers serve the pilot outside the examination room:
- Icing. The freezing level from the surface temperature, set against the forecast cloud base and tops, gives the band of cloud at sub-zero temperatures where airframe icing is possible. An inversion can put the temperature through 0 °C more than once, and a warm layer above sub-zero surface air is the setting for freezing rain (see airframe icing).
- Convection. The spread at the surface gives the height of the cumulus base; the ELR against the SALR tells whether that cumulus will stay small or grow. Thunderstorms need moisture, instability through a deep layer and a trigger together (see thunderstorms).
- Performance. A strong inversion aloft means that air a few thousand feet up is warmer than the surface temperature suggests, and thrust and climb gradient fall as the aircraft climbs into it. The Chinook, the föhn of the Rocky Mountains, can raise the temperature on their lee side by 20 °C in 15 minutes, with the density altitude rising accordingly (see density altitude).
Exam tip: the numbers to carry are ISA 2 °C (3.5 °F) per 1,000 ft for air at rest; DALR 3 °C (5.4 °F); SALR about 1.5 to 1.8 °C, varying; dew point 0.5 °C (1 °F); and a spread that closes at 2.5 °C (4.4 °F) per 1,000 ft, so 400 ft per degree Celsius.
Frequently asked questions
What are the values of the DALR and the SALR?
The dry adiabatic lapse rate is 1 °C per 100 m, about 3 °C (5.4 °F) per 1,000 ft, and it is constant. The saturated adiabatic lapse rate varies: EASA ATPL texts give about 0.6 °C per 100 m (1.8 °C per 1,000 ft) near the surface in temperate latitudes, PPL questions often use 1.5 °C per 1,000 ft, and the FAA quotes a range of 1.1 to 2.8 °C per 1,000 ft.
What is the difference between the environmental lapse rate and the adiabatic lapse rates?
The environmental lapse rate is the temperature profile of the real atmosphere at a given place and time, measured by radiosonde, and it describes air at rest. The adiabatic lapse rates describe how a parcel of air changes temperature when it rises or sinks: at the dry rate while unsaturated, at the slower saturated rate once cloud forms. Stability is found by comparing the two.
How do you calculate the cloud base from temperature and dew point?
In rising unsaturated air the temperature falls about 3 °C per 1,000 ft and the dew point about 0.5 °C, so the spread closes at 2.5 °C per 1,000 ft, or 400 ft per degree. A temperature of 24 °C and a dew point of 14 °C give a convective cloud base near 4,000 ft above the surface. With Fahrenheit readings, divide the spread by 4.4 and multiply by 1,000 ft.
Why is the standard lapse rate 2 °C per 1,000 ft and not 3 °C?
The 2 °C figure, more exactly 1.98 °C per 1,000 ft, is the environmental lapse rate of the ICAO Standard Atmosphere, an average profile of air at rest used for altimetry and performance. The 3 °C figure is the dry adiabatic lapse rate, the cooling of a rising unsaturated parcel. Use 2 °C to estimate the temperature at a level or the freezing level, and 3 °C only for air that is moving vertically.
What lapse rate makes the air conditionally unstable?
Any environmental lapse rate between the saturated and the dry adiabatic rates, such as 0.8 °C per 100 m or 2 to 2.5 °C per 1,000 ft. Unsaturated air lifted in such a profile becomes colder than its surroundings and sinks back, but once lifted beyond its condensation level it cools more slowly than the environment and, if lifted far enough, becomes warmer and rises freely. The condition is saturation, reached only with a trigger.
Test yourself on Lapse Rates: ELR, DALR and SALR
The v1prep banks cover this topic in Meteorology (050), with a worked explanation for every answer. EASA ATPL, PPL, IR and CPL, the FAA written tests and type ratings for the A320, A330, A350, 737, 767, 777, A220, 787, ATR 72 and E-Jet.
Start practicing →Sources and further reading
- FAA Pilot's Handbook of Aeronautical Knowledge (FAA-H-8083-25C), Chapter 12, Weather Theory
- FAA-H-8083-28B, Aviation Weather Handbook
- FAA Advisory Circular AC 00-6B, Aviation Weather (canceled, content now in FAA-H-8083-28)
- ICAO Doc 7488, Manual of the ICAO Standard Atmosphere (extended to 80 kilometres (262 500 feet)), ICAO Store
- EASA, Explanatory Note to ED Decision 2018/001/R, Part-FCL theoretical knowledge learning objectives
- American Meteorological Society, Glossary of Meteorology, lapse rate
Library articles are written for study and exam preparation. They do not replace your aircraft's approved documentation, your operator's procedures or the regulations themselves.